1 Relay rating
Common type(XMT):working current 4mA~6mA;working voltage 80VDC~300VDC.
(2 group contacts can be 50VDC~300VDC)High sensitivity type(XMS): working current 3mA~4.5mA;working voltage 50VDC~300VDC.(AC: working current increase 2mA)
2 Contact capacity 250VDC, 0.1A,Prohibit testing insulation and endurance voltage of contact.Contact can be applied only in signal loop.
3 Retaining value 0.7~1.2 times to rating voltage The operating and resetting time of the JZ-7 series auxiliary relay is less than 15ms.
4 Power consumption Type XMT: Less than 1.1W under 220VDC.Type XMS: Less than 0.9W under 220VDC.3.5 Insulation resistance Measured with 1000V tramegger, the insulation resistance of every fetch out terminal to the shell fix-screw more than 10 MΩ.
6 Insulation and endurance voltage The limited power frequency voltage of every
fetch out terminal to the shell fix-screw is 2000V. The limited value among the con-
tacts of the one group is 1000V. And after test for 1 minute, there is no break off.
7 Electrical endurance 250VDC, 0.1A, above 104 times.
8 Mechanical endurance More than 3 million (contact with no charge).
XMT/XMS TYPE SERIALS STATIC MONITORING
CLOSING POSITION,TRIPING POSITION,
POWER-STATE RELAY(JZ-7GY-S002XMT)
XMT/XMS TYPE SERIALS STATIC MONITORING
CLOSING POSITION,TRIPING POSITION,
POWER-STATE RELAY(JZ-7GY-S020XMS)
XMT/XMS TYPE SERIALS STATIC MONITORING
CLOSING POSITION,TRIPING POSITION,
POWER-STATE RELAY(JZ-7GY-S040XMT)
XMT TYPE SERIALS STATIC MONITORING
CLOSING POSITION,TRIPING POSITION,
POWER-STATE RELAY(JZ-7GY-S202XMT)
XMT TYPE SERIALS STATIC MONITORING
CLOSING POSITION,TRIPING POSITION,
POWER-STATE RELAY(JZ-7GY-S220XMT)
XMT TYPE SERIALS STATIC MONITORING
CLOSING POSITION,TRIPING POSITION,
POWER-STATE RELAY(JZ-7J-203XMT)
Contact Person: Ms. Biona
Tel: 86-755-83014873
Fax: 86-755-83047632
APF7.820.077C PCB for ESP voltage controller spare, voltage and current signal process
380V AC Industrial Frequency Power ESP Controllers EPIC-III Controller Sampling Board, Trigger Board
Ignition Cble XDL-l B Explosion Proof High Performance Ignition System Device Cable Length 2, 3, 6m
Coal Feeder Spare main board , CPU board 9224 / CS2024 / EG24 ( Micro board )
Coal Feeder Spare degree probe for 9224 / CS2024 coal feeder, CS19900, C19900, CS8406
Coal Feeder Spare CS2024 and 9424 special coal feeder belt for electronic weighing type