Send Message
Home ProductsLow Voltage Protection Devices

Powerful Low Voltage Protection Devices Explosion-Proof Soft Starter

Powerful Low Voltage Protection Devices Explosion-Proof Soft Starter

  • Powerful Low Voltage Protection Devices Explosion-Proof Soft Starter
Powerful Low Voltage Protection Devices Explosion-Proof Soft Starter
Product Details:
Place of Origin: China
Brand Name: OEM
Model Number: LZR1-3
Payment & Shipping Terms:
Minimum Order Quantity: 1 set
Packaging Details: Wooden box packing
Delivery Time: 15 days after signing the contract
Payment Terms: T/T
Supply Ability: 1000sets
Contact Now
Detailed Product Description
High Light:

low voltage protection circuit

,

dc power contactor

Powerful Low Voltage Protection Devices Explosion-Proof Soft Starter

 

 

 

Introduction
The LZR1 series not only have the functions of normal starter which used in domestic at present, but also own their special functions:
1. High power inner bypass design is the main advantage of LZR1 series, this design avoid much problems which occur in the design of outer
bypass design . Inner byass design makes the softer functions is more useful and the installation is more simply. Inner bypass makes the primary
circuitry is more simply, it is very easy to install and won't cause trouble. Inner bypass makes the secondary circuitry also can be mastered easily.
LZR1 series soft starter is the first time in China using inner bypass design, its power range is 5.5~400kW. We applied the patent for LZR1 soft starters.
The patent numbers are ZL 200630038542.4 and ZL 200620044145.2 .
2. LZR1 soft starter adopts the imported Germany square chip and advanced chip support pole, uses DCB ware and copper integrating board,
through the special processing method and welding skill, keep the welding layer without space, and keep the good heat conduct. The head loop load
is 10 times higher than the GB standard.
3. LZR1 series soft starter integrates the high power intelligent controlling thyristor module and full digital shift touch-off integration circuit into
one body. The product owns small body and strong anti-interfere functions, as well as the advantages of anti-earthquake anti-humidity, so it is the
priority products used in the flammable and explosive environment.
4. Inner bypass installation is a big system project which is developed at the base of adopting many advanced science and technical elements
as well as modern science theory. The starter first control part adopting the advanced chip microprocessor as control center. With the help of
adopting advanced electrical control program theory, full digital phase shift technique, high power non-arc and long lifetime contactor technique,
so the starter integrating all the advantages. As well known the difference of contactor and relay is that the contactor has arc eliminator, while relay
without arc eliminator. The LZR1 soft starter equipped an arc eliminator inside the inner installation, so it can be connected with the high power load
and high voltage load.
5. User friendly, easy setting and operation: LZR1 adopting the LCD display, it can display each start method, start time, primary voltage and
soft stop time. It is very easy to control for the user. The user can program the motor starter mode with the help of th e instruction. The LCD display
screen display all the data, such as work mode, current position and soon, in this case, it is very easy for the user to set and operate.
6. LZR1 series have the strong protection function, it adopts JDG1 type motor compositive protector and related interface, so it supplies motor
strong protection when the motor under the situation of phase failure, over load, over voltage ,jam swivel and short voltage. The starer also equipped
the heat protector inside the body and protects itself.
7. LZR1 series can be controlled from the LCD screen, it also can be controlled through the computer in the control room. LZR1 series products
own the excellent controlling ability; it can adjust the urgent stop, soft stop and soft start.
8. LZR1 series products’ inner bypass installation is non-power running mode, it is different from the out by pass installation starter, so it has the
advantages of saving energy, no noise, no electromagnetism pollution and protect environments.

Technical Index of Soft Starter

 

Applicable Standard

LZR1 electronic motor soft starter has passed the certificate of 3C, complied with national standard GB14048.6-1988.

3 Phase power
Source voltage(U)      V

380V±15% 660V±15% 1140V±15%

Frequency                   Hz

50

Rated  Current            A

10A ~ 800A total 18 specifications

Rated  Power              KW

5.5~400kW

Rated  Voltage            V

3806601140

Current Regulation

The rated  current IQ of motor, It can adjust under 0.5~3.5 times of rated startup current, limit the startup current below 5 times of peak start current .

Startup Mode

User should set by himself according to the connected load and instruction of manual

Shutdown Mode

1, Naturally shutdown    2, Soft shutdown     3, 5S~60S set by user

Nos of Startup

12 times/hour, complied with GB14048.6AC-53b

Display and Keyboard

Under normal working it can display the status of motor, shows fault , the key-board can be set and programmed.

Output relay (2pcs)

NO, NC contact output of fault (Non-source contact)

Fan working status

1Long term work        2Run/Stop and outer switch control
3It is also can control by internal temperature control switch

Protection

1.Phase failure protection: LZR1 series soft starter has provided the phase failure protection,  the tripping time
for phase failure complies with inverse time delay characteristics, namely bigger over-current has shorter tripping
time
2.Over-current protection: LZR1 series soft starter has provided over-current protection, with inverse time
delay tripping characteristics.
3.Fast cut protection: LZR1 series soft starter has provided the fast cut protection as well, when urgent
stop required, it can realize by use of  fast cut protection.
4.Thermal protection:when the starter is overheat and the inner temperature more than 75℃,
starter will auto-matically cut off.
5.Thermal protection: when the starter is overheat and the inner temperature more than 75, starter will auto-
matically cut off.

 

Contact Details
Hontai Machinery and equipment (HK) Co. ltd

Contact Person: Ms. Biona

Tel: 86-755-82861683